catégorie

Oil Immersed Transformer | IEC 60076 Certified Copper Winding Transformer | Xinhong Electrical

High quality oil immersed transformers from China factory. 100kVA–25MVA, pure copper winding, IEC60076, CE, ISO, CB certified. For solar, grid, industrial and EPC projects worldwide.
Oct 28th,2026 13 Vues

Introduction

Oil immersed transformer is the most widely adopted power transformer for power grid, solar/wind boost station, industrial park and mining projects globally. Compared with dry type transformers, oil immersed transformers feature lower cost, better heat dissipation, higher overload capacity and longer service life, which makes it the preferred solution for medium and large power distribution systems.

Xinhong Electrical is a professional Chinese manufacturer with 15 years export experience. Our oil immersed transformers adopt pure copper winding, strictly designed and tested per IEC 60076 standard, available with CE, ISO and CB certifications. We supply units from 100kVA to 25MVA for clients in Africa, Southeast Asia, Central Asia and the Middle East.

What is an oil immersed transformer?

An oil immersed transformer is a transformer whose core and windings are submerged in insulating mineral oil. The transformer oil works as both insulation medium and heat transfer medium. Heat generated during operation is transferred to the tank surface and radiated into ambient air.

Common cooling modes include ONAN (Oil Natural Air Natural) and ONAF (Oil Natural Air Forced). It is mainly used for outdoor installation, substation, solar booster station and heavy-duty industrial load.

What are the advantages of oil immersed transformers?

  • Excellent heat dissipation: Suitable for continuous heavy load and occasional overload
  • Lower unit cost at large capacity: More cost-effective than dry type transformer above 1000kVA
  • Stable dielectric performance: Good resistance to voltage surge and lightning impulse
  • Long service life: Proper maintenance can reach 25–30 years design life
  • Easy repair and on-site maintenance: Convenient oil testing, filtering and component replacement

What are the main components of oil immersed transformer?

  • Transformer tank & radiator
  • Core and pure copper winding
  • Conservator (oil expansion tank)
  • Buchholz relay (gas relay)
  • OLTC or off-circuit tap changer
  • Oil level indicator, temperature gauge, pressure relief valve
  • Bushing for high voltage and low voltage connection

What standard does your oil immersed transformer follow?

All our oil immersed transformers comply with IEC 60076 series standards, including routine tests, type tests and special tests as required. We can also adjust design to meet local grid requirements for different countries. Certifications including CE, ISO 9001, CB test reports are available for tender submission and inspection.

Common technical parameters for selection

  • Rated capacity: 100kVA ~ 25MVA
  • Voltage level: 6kV, 10kV, 20kV, 35kV
  • Cooling method: ONAN / ONAF
  • Winding material: Pure copper (optional aluminum upon request)
  • Vector group: Dyn11, Yyn0, Yd11
  • Insulation oil: Mineral insulating oil
  • Protection: Buchholz relay, over-temperature protection, pressure relief

Oil Immersed Transformer VS Dry Type Transformer: How to choose?

This is the most frequent question raised by EPC engineers and project buyers.

  • Oil immersed transformer: Outdoor use, large capacity, lower cost, better cooling, requires fire isolation, regular oil maintenance. Best for solar farm, grid substation, mining.
  • Dry type transformer: Indoor use, fire safety, no oil maintenance, higher price. Best for hospital, shopping mall, metro, building power room.

What tests will be carried out before delivery?

Following IEC 60076 requirements, every oil immersed transformer will finish routine tests before shipment:

  • Winding resistance test
  • Voltage ratio & vector group check
  • No-load loss and no-load current test
  • Load loss test
  • Power frequency withstand voltage test
  • Tap changer operation test

Type tests including temperature rise test, lightning impulse test and short-circuit withstand test are available on request for tender projects.

FAQ about oil immersed transformers

Q1: Can oil immersed transformers be installed indoors?

A: Yes, but fire prevention and oil collection pit are mandatory according to local electrical codes. Most clients prefer dry type transformers for indoor crowded public areas.

Q2: How often do I need to test transformer oil?

A: Normally DGA (dissolved gas analysis) test once per year for grid transformers. For solar farm transformers, oil testing every 12–24 months is recommended.

Q3: What is the difference between ONAN and ONAF?

A: ONAN means natural cooling without fan; ONAF uses cooling fans to enhance heat dissipation, supporting higher continuous loading capacity.

Q4: Can you customize tap voltage and vector group?

A: Yes, our engineering team supports custom design for voltage ratio, vector group and accessories according to your project specification.

Get IEC 60076 Certified Oil Immersed Transformers from Xinhong Electrical

We are a direct factory located in Jiangsu, China, with 27000㎡ production workshop. All our copper winding oil immersed transformers are built under IEC 60076 and fully inspected before shipment.

Send your capacity, voltage, cooling method and project location to our sales team. We will offer technical datasheet, test plan and formal quotation for your power project.