catégorie

Structural Characteristics of Dry‑Type Transformers

Aug 10th,2026 16 Vues

1. What Is a Dry‑Type Transformer?

A dry‑type transformer, as the name implies, is a transformer whose core and windings are not immersed in insulating oil. Unlike traditional oil‑immersed transformers, dry‑type transformers rely on air or solid insulating materials (such as epoxy resin) to achieve insulation between windings and to dissipate heat. Their cooling methods are mainly classified into natural air cooling (AN) and forced air cooling (AF) – under natural air cooling, the transformer can operate continuously at rated capacity, while under forced air cooling, the output capacity can be increased by up to 50%.

Thanks to their safety, fire resistance, and pollution‑free nature, dry‑type transformers are widely used in places with high fire‑protection and environmental requirements, such as local lighting, high‑rise buildings, airports, docks, and CNC machinery equipment.


2. Core Structure of a Dry‑Type Transformer

The structure of a dry‑type transformer mainly consists of three core components: the core (magnetic circuit), the windings (coils), and the insulation system, supplemented by auxiliary parts such as the enclosure and temperature control system.

2.1 Core (Magnetic Circuit)

The core is the magnetic circuit of the dry‑type transformer and plays a central role in electromagnetic energy conversion.

Material – The core is typically made of high‑quality cold‑rolled grain‑oriented silicon steel sheets, coated with insulating varnish to prevent moisture and rust. Some high‑end products use imported high‑grade silicon steel from Japan to further reduce losses.

Structural process – The silicon steel sheets are arranged in a 45° full‑miter joint design, allowing magnetic flux to pass smoothly along the joint direction, thereby reducing magnetic reluctance and core loss. Modern dry‑type transformers often adopt stepped lap joints and non‑punching, tie‑plate structures, further reducing no‑load loss and operating noise. Transformers with a three‑dimensional wound core have no lap joints between core layers, resulting in uniform flux distribution throughout the magnetic circuit, which effectively reduces no‑load loss and no‑load current compared with conventional laminated cores.

2.2 Windings (Coils)

The windings form the electrical circuit of the dry‑type transformer and are divided into high‑voltage (HV) windings and low‑voltage (LV) windings, both coaxially mounted on the core limbs.

LV windings are mostly of foil‑type construction, wound from high‑quality copper foil and insulating materials. This structure offers high mechanical strength, strong short‑circuit withstand capability, and good thermal shock resistance. Some products use a phenolic paper tube as support, with spacers filling the gap between the tube and the core to prevent radial displacement of the coil, thus reducing operating noise.

HV windings adopt a continuous‑disc construction, wound on an insulated forming cylinder using rectangular insulated copper wire. Compared with conventional multilayer cylindrical coils, the continuous‑disc structure provides better heat dissipation and higher mechanical strength, while avoiding problems such as high inter‑layer voltage and thermal breakdown.

An insulating cylinder is placed between the HV and LV windings to increase electrical insulation, and the windings are supported and constrained by spacers and clamping blocks, with all fasteners designed to resist loosening.

2.3 Insulation System

The insulation system is the key feature that distinguishes dry‑type transformers from oil‑immersed ones. Currently, the mainstream insulation methods include the following three:

  1. Epoxy resin casting (thin‑insulation structure) – The windings are cast under vacuum using glass‑fibre‑reinforced epoxy resin. The composite material has a thermal expansion coefficient close to that of copper conductors, providing excellent resistance to impact, temperature cycling, and cracking. The resin mixture completely penetrates into the gaps between the coils, firmly bonding the windings and insulation into an integrated body with very high mechanical strength. Some products add fillers and flame retardants to the epoxy resin to further enhance impact resistance and flame retardancy.

  2. Epoxy resin with quartz‑sand filling – Quartz sand is added to the epoxy resin as a filler to improve the mechanical strength and thermal conductivity of the insulation layer.

  3. Vacuum Pressure Impregnation (VPI) – Insulating paper is used as the base insulation material, and the coils are impregnated under vacuum and pressure to form a solid, rugged whole. This method offers excellent moisture resistance, withstands thermal shock without cracking, and can achieve partial‑discharge levels below 5 pC.


3. Main Features of Dry‑Type Transformers

In summary, dry‑type transformers exhibit the following outstanding characteristics:

1. Safe, environmentally friendly, fire‑resistant and pollution‑free
They contain no flammable insulating oil, so there is no risk of oil leakage causing fire or environmental contamination. They can be installed directly at load centres.

2. High mechanical strength and strong short‑circuit withstand capability
Thanks to advanced casting or impregnation processes, the windings and insulation are firmly integrated, giving the whole structure high mechanical strength and effective resistance to the electrodynamic forces generated by sudden short circuits.

3. Low losses, low noise, energy‑saving and maintenance‑free
With high‑quality silicon steel and advanced structural design, both no‑load and load losses are low; operating noise is minimal, and no regular oil‑change or other maintenance work is required.

4. Good heat dissipation and high overload capacity
Under forced air cooling, the output capacity can be significantly increased, making them suitable for intermittent overload or emergency operation.

5. Excellent moisture resistance and adaptability to harsh environments
The solid encapsulation makes the transformer insensitive to humidity, dust, salt spray, and other environmental factors, making it suitable for high‑humidity and other severe conditions.

6. Intelligent temperature monitoring and protection system
Dry‑type transformers can be equipped with comprehensive temperature detection and protection systems. An intelligent signal temperature controller automatically detects and sequentially displays the operating temperatures of the three phases, starts and stops the fans automatically, and provides alarm and trip functions.

7. Compact size, light weight, and low installation cost
Compared with oil‑immersed transformers, dry‑type transformers occupy less floor space and do not require auxiliary facilities such as oil containment pits, resulting in lower installation costs.


4. Technical Standards and Applicable Codes

In the Chinese market, the manufacture of dry‑type transformers must strictly comply with the following national standards:

  • GB/T 1094.11 – Power Transformers – Part 11: Dry‑Type Transformers

  • GB/T 10228 – Technical Parameters and Requirements for Dry‑Type Power Transformers

  • GB/T 20052 (relevant energy‑efficiency requirements)

These standards comprehensively specify the ratings, temperature‑rise limits, insulation levels, climate and fire‑performance classes, seismic characteristics, test methods, and other aspects of dry‑type transformers.


5. Xinhong Electrical Dry‑Type Transformer Solutions

Xinhong Electrical (Jiangsu Xinhong Electrical Equipment Co., Ltd.) is a professional power‑equipment manufacturer integrating R&D, manufacturing, trading, and service. Its core product portfolio covers dry‑type transformers, oil‑immersed transformers, HV/LV switchgear, and complete electrical solutions.

In the dry‑type transformer field, Xinhong Electrical offers various standard and custom capacities, including 630 kVA, 800 kVA, and 1000 kVA, widely used in commercial buildings, industrial projects, and various power‑distribution scenarios. The company insists on using full copper windings to ensure lower losses, higher overload capability, and excellent heat dissipation.

As a professional OEM manufacturing partner, Xinhong Electrical provides a full range of services, including technical scheme design, documentation preparation, installation guidance, and global after‑sales support, backed by a 2‑year warranty. All products are manufactured in strict accordance with Chinese national standards (GB) and International Electrotechnical Commission (IEC) standards, dedicated to delivering high‑quality, high‑performance dry‑type transformer solutions to customers worldwide.


Conclusion

With their unique advantages of safety, environmental friendliness, compact structure, and reliable performance, dry‑type transformers are playing an increasingly important role in modern power distribution systems. From the selection of high‑quality silicon steel for the core, to the foil‑type and continuous‑disc winding designs, to advanced insulation processes such as epoxy resin casting and VPI impregnation – every structural detail determines the operating efficiency and service life of the transformer. As national requirements for power‑equipment energy efficiency continue to rise, dry‑type transformers, driven by their low‑loss, maintenance‑free, and intelligentdevelopment direction, are sure to enjoy even broader application prospects.