• S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation

S13-10000kva oil-immersed step-up transformer for photovoltaic power generation


This product is a large-scale power distribution equipment that integrates high efficiency and energy saving, full-seal maintenance-free operation, high reliability, and smart capabilities. It serves not only as the core component for power transmission but also as an ideal solution for reducing operating costs, ensuring power supply security, and achieving green energy-saving goals. It is widely suitable for critical applications such as urban power grids, industrial and mining enterprises, power plants, new energy power stations (PV/wind power), commercial centers, airports, and rail transit systems.

  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation
  • S13-10000kva oil-immersed step-up transformer for photovoltaic power generation

Description

Product Features

1. High Efficiency and Energy Saving, Economical and Environmentally Friendly

Utilizes high-permeability silicon steel sheets and advanced multi-step laminated core technology to significantly reduce no-load and load losses.
Product performance meets or exceeds the Grade 1 energy efficiency standard specified in the Chinese national standard "Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Power Transformers" (GB 20052-2020), delivering outstanding energy-saving effects and effectively lowering long-term operating costs.

2. Fully Sealed Structure, Maintenance-Free Design

Features a corrugated tank or膨胀式散热器 (expansion radiator) structure, completely isolating the transformer oil from air to prevent ingress of oxygen and moisture, thereby slowing insulation aging.
Eliminates the need for a traditional conservator, removing the requirement for periodic oil level checks and achieving true maintenance-free operation throughout its lifecycle, saving on maintenance costs.

3. Rugged and Reliable, Safe and Stable

The core is secured with high-strength tightening bands and treated with special processes, providing strong short-circuit and impact resistance to withstand mechanical stresses during transportation and operation.
The tank structure is robust with a high protection rating (e.g., IP rating), making it suitable for harsh industrial environments.

4. Excellent Electrical Performance

Employs Computer-Aided Design (CAD) and optimized electromagnetic field technology, resulting in low partial discharge, reliable insulation, and strong lightning impulse withstand capability.
Offers both off-circuit and on-load tap-changing options for easy voltage adjustment, meeting the needs of grid voltage fluctuations.

5. Environmentally Friendly and Safe

Options available for high-performance fire-resistant fluids (e.g., β-fluid) or natural ester insulating oil (vegetable oil), featuring high fire points and biodegradability. Ideal for locations with stringent fire safety and environmental requirements (e.g., indoor spaces, shopping malls, subways, schools).


Product Advantages

1. Low Total Cost of Ownership
Extremely low no-load and load losses translate to substantial electricity cost savings over the product's entire lifecycle (typically 20-30 years), offering a high return on investment.

2. Long Service Life
The fully sealed structure ensures a dry and pure internal insulation system, with a design life extending over 30 years.

3. High Reliability for Uninterrupted Power Supply

Enhanced short-circuit withstand capability and reliable insulation design minimize the risk of power outages caused by transformer failures, ensuring stable power supply for grids and end-users.

4. Wide Environmental Adaptability

Suitable for various harsh conditions such as high altitude, high humidity, high pollution, and salt mist environments, covering diverse geographical and climatic regions across the country.

5. Smart Connectivity

Can be equipped with comprehensive online monitoring devices (e.g., TMU) for parameters like temperature, pressure, and gas, enabling easy integration into IoT systems. This allows for real-time condition monitoring, fault warning, and intelligent maintenance, providing a foundation for smart grid construction. 